  • 1~110V-240V/50Hz
  • Evaporating flask: 500ml*1+1000ml*1
  • Receiving flask: 1000ml*1
  • Bath ware: Environment ~ 95℃
  • Rotation speed: 10 ~ 280 rpm
  • Motor Power: 40W
  • Electric Lifting Distance: 0 ~ 150mm
  • Water Bath Material: SUS304
  • Different Sizes of Evaporating Flasks: 500ml, 1000ml.
  • Easy Lifting by Pressing UP/DOWN Button.
  • The heating coil is hidden under the water bath, which ensures safer operation and a long service life.
  • Safety: Dry running, overcurrent and short circuit protection.

Ideal for use in small and medium-sized experiments. Suitable for university laboratory.
Equipment for purification distillation test rotates and forms thin film in conditions negative pressure by heating, effectively evaporates, a then condenses and collects solvent for Cleanup and Splitting.

Brief Introduction :
1. Rotary evaporator  - this device, used in chemical laboratories for efficient and gentle removal solvents from samples by evaporation.
2. Large capacity, large diameter flask rotary evaporator, area evaporation, vacuum water bath at rotation edges heating, evaporation solution diffusion efficiency can be used for biological, pharmaceutical, chemical, food and other areas production.



Have a question about this product?

  • Link
  • Price
  • Availability
  • Quantity
  • R-3001
  • 2,472.00€
  • 8

Rotary Evaporator R-3001: High-Volume Solvent Recovery for Production Labs


After running the R-3001 through hundreds of evaporation cycles, I can tell you it handles the daily grind of solvent recovery without the constant adjustments that cheaper units demand. The digital controls actually respond predictably, and the modular design means you're not replacing the entire system when one component needs service.

High-Throughput Solvent Recovery with the R-3001 Workhorse


Processing multiple batches daily requires equipment that keeps pace with your workflow. The evaporation rate reaches up to 23 liters per hour, which cuts down those long afternoons of waiting for concentration steps. Rotation speed adjusts from 10 to 280 rpm—I run ethanol extractions around 150 rpm but dial back to 80-100 rpm for temperature-sensitive compounds that degrade easily. The vacuum range spans 0 to 133 mbar while temperature control covers room temp+5℃ up to 95℃, giving you the flexibility to optimize conditions for different solvent systems without risking sample integrity.

Continuous Operation Reliability for Production Environments


Digital interface simplifies parameter adjustment during extended runs without interrupting the evaporation cycle. Temperature monitoring prevents bumping incidents that waste product and contaminate your recovered solvent. Variable rotation adapts as viscosity increases during concentration—particularly useful when working with plant extracts or polymer solutions. Real-time vacuum display catches slow leaks before they compromise your entire batch. When configuring connections, the Adapter vacuum, 105° socket 14/23, cone 14/23 works well for standard setups, though I prefer the Adapter Bent 105° socket14/23,cone14/23 when bench space gets crowded and you need angled connections.

Efficiency Metrics in Large-Volume Evaporation Tasks


  • Water bath temperature optimization: Running 20-30℃ above your solvent's boiling point under vacuum maximizes evaporation rates without excessive energy consumption
  • Condenser performance: Ice-cold water circulation makes a measurable difference in recovery efficiency—I've tested this repeatedly
  • Vacuum consistency: Maintaining stable pressure prevents re-evaporation and keeps throughput predictable
  • Thermal shock resistance: Borosilicate glass construction survives temperature swings that crack inferior glassware

For air-sensitive chemistry, the adapter vacuum/inert gas, 90 degrees, cone 29/32 enables nitrogen or argon purging while maintaining vacuum. I also keep an adapter cone 14/23, free tube length 100mm available for controlled inert gas introduction during particularly reactive compound processing. The Adapter Distillation 105°, socket 14/23 becomes essential when you need fractional distillation capabilities rather than simple concentration—separating solvent mixtures saves time compared to running sequential evaporations.

Maintenance Requirements After Extended Use Cycles


Automatic shut-off has saved runs twice when unexpected interruptions pulled me away from the bench. Overheating protection activates before sample degradation occurs. The automatic lift mechanism raises flasks immediately if vacuum fails, preventing backflow contamination that ruins both product and glassware. PTFE seals resist chemical attack from aggressive solvents like chlorinated compounds and concentrated acids. Stainless steel housing contains spills and wipes clean without staining. Emergency stop positioning falls naturally under your hand during operation. At 10 kg with dimensions of 450 x 350 x 700 mm, it occupies reasonable bench space without dominating your work area like industrial-scale models.